\section[Luminosity Measurements at \bes3]{Luminosity Measurements at
\bes3\footnote{By X.~H.~Mo, C.~D.~Fu, K.~ L.~He}}
\label{part1:sec:lumi}


\subsection{Introduction}\label{xct_intd}

With the large data samples that will be collected at \bes3
--- typically a few fb$^{-1}$--- unprecedented statistical precision 
will be achieved in the analyses of many channels.  Thus, 
non-statistical factors and effects will be the limiting factors 
on the precision of many experimental results.
Foremost among these limiting factors
will be the luminosity, which will be an 
input to many precision measurements, including the $\tau$ mass
measurement, $R$-values, $J/\psi$, $\psi^{\prime}$ and $\psi^{\prime 
\prime}$ total widths etc.  For these quantities, the luminosity error 
will directly translate into errors on their measured values. 
Thus, precision  luminosity measurements are a very important
aspect of the \bes3 physics program.

In $e^+e^-$ colliding beam experiments, generic physics analyses
commonly require the precise knowledge of the relative luminosity 
accumulated  on and off a resonance peak  so backgrounds from 
continuum production can be reliably subtracted. 
Some  analyses  make  internal consistency checks 
by dividing the full dataset into independent subsets
of comparable size. Here again there will be strong reliance
on the accuracy and stability of the
relative luminosity measurements. In addition, 
events used to calculate  the
luminosity, such as $e^+e^-$, $\mu^+\mu^-$ and $\gamma\gamma$, 
are interesting in their own right because of their
salient topologies that make them useful for online 
performance monitoring.

\begin{figure}[hbt]
\centerline{\psfig{file=./Part1/figures/xksh1.eps,height=8.0cm ,width=7.5cm}}
\caption{\label{qedxct} Differential cross sections for the QED
processes: $e^+e^- \to e^+e^-$, $e^+e^- \to \mu^+\mu^-$, and $e^+e^- \to
\gamma\gamma$. The
center-of-mass energy  is 3.5 GeV.}
\end{figure}

In principle, any known process can be used to
measure luminosity.  However,
in order to obtain precise results, one usually selects a
process that has a characteristic experimental topology 
and a cross section that can be precisely calculated.
The QED processes
$e^+e^- \to e^+e^-$, $e^+e^- \to \mu^+\mu^-$, and
$e^+e^- \to \gamma\gamma$ satisfy these criteria 
and are commonly used for luminosity measurements. Their
differential cross sections, shown in Fig.~\ref{qedxct}, 
have the forms:
$$ \left. \frac{d\sigma}{d\Omega} \right|_{e^+e^- \to e^+e^-}
= \frac{\alpha^2}{4s} \left( \frac{ 3+\cos^2 \theta}{ 1-\cos
\theta}\right)^2~~, $$
$$ \left. \frac{d\sigma}{d\Omega} \right|_{e^+e^- \to \mu^+\mu^- }
= \frac{\alpha^2}{4s} \left( 1+\cos^2 \theta \right)~~, $$
$$ \left. \frac{d\sigma}{d\Omega} \right|_{e^+e^- \to \gamma\gamma }
= \frac{\alpha^2}{4s} \left( \frac{ 1+\cos^2 \theta}{
(E_b/p)^2-\cos^2 \theta} \right)^2~~. $$

The experimental response of the detector to each of these
reactions is quite distinct: their detection
efficiencies rely on  charged particle
tracking ($e^+e^-$ and $\mu^+\mu^-$), calorimetry ($e^+e^-$ and 
$\gamma\gamma$), muon identification ($\mu^+\mu^-$), and trigger 
algorithms. The expected theoretical cross
sections are calculable in QED;  at BEPCII energies weak interaction
effects are negligible. The primary theoretical obstacle in all
cases is the computation of electromagnetic radiative 
corrections in
a way that accommodates the experimental event selection criteria 
with adequate precision. This is usually accomplished by
Monte Carlo event generators that include diagrams with a
varying number of virtual and real radiative photons. In general,
the more accurate the theoretical calculation  the 
smaller the uncertainty on the luminosity measurement.

\begin{figure}[hbt]
\centerline{\psfig{file=./Part1/figures/cmpcmpn.eps,height=6.0cm,width=8.cm}}
\caption{\label{cmphup} Cross sections in the vicinity of $\psi(2S)$
for (a)~inclusive hadrons  and (b)~$\mu^+\mu^-$ (b) final states.
The solid line and arrow indicates the observed peak position
and the dashed line and arrow the actual position of the resonance
peak. In (b), the dashed line indicates the QED continuum~($\sigma^C$),
the dotted line he resonance~($\sigma^R$), the
dash dotted line the interference~($\sigma^I$), and
solid line the total cross section~($\sigma^{Tot}$).}
\end{figure}

Other factors that cannot be neglected are  interference effects
in the vicinity of resonance peaks. Such effects not only distort
the cross sections in the peak regions but 
can also shift the resonance peak position,
as the example shown in Fig.~\ref{cmphup} 
demonstrates. Resonance-continuum cross section ratios 
for the $J/\psi$, $\psi^{\prime}$, and $\psi^{\prime \prime}$ regions are 
listed in Table~\ref{rescon}. From the table we can see
that in the continuum region all three of the QED processes listed above
can be used to determine the luminosity, while only 
$\gamma\gamma$ and $e^+e^-$ can be used for the $\psi^{\prime}$, 
and only $\gamma\gamma$ is suitable for the $J/\psi$, if
high accuracy  is not to be compromised.

\begin{table}[htb]
\caption{\label{rescon}Resonance-continuum cross section ratios
in the $J/\psi$, $\psi^{\prime}$, and $\psi^{\prime \prime}$ 
peak regions.} \center
\begin{tabular}{c|ccc} \hline \hline
Res./Con. &  $J/\psi$   & $\psi^{\prime}$     & $\psi^{\prime \prime}$               \\  \hline
  $\mu^+\mu^-$   &  15.3      &  0.625     & $<1.28\times 10^{-5}$ \\
  $e^+e^-$   &  0.700     &  0.027     & $6.0\times 10^{-5}$   \\
  $\gamma\gamma$   & $<6\times 10^{-3}$
                       & $<5.8\times 10^{-3}$
                            & $<5.8\times 10^{-3}$  \\
\hline \hline
\end{tabular}
\end{table}

\subsection{Event selection and Algorithm}\label{xct_evt}

A detailed Monte Carlo simulation has been performed to develop
the event selection criteria listed in Table~\ref{lumevetsel}.
This is preliminary and is used as an example to study systematic 
errors  and identify what  further studies are needed. 

\begin{table}[htb]
\caption{\label{lumevetsel}Selection criteria for $e^+e^-$, $\gamma\gamma$, and
$\mu^+\mu^-$ final states.}
\center
\begin{tabular}{l|ccc} \hline \hline
      Description         & $e^+e^-$          & $\gamma\gamma$        & $\mu^+\mu^-$        \\ \hline
   \# neutral tracks      &        &  $\ge 2$     &              \\
   \# charged tracks      & $\ge 2$ ($<n$,
                            $n$ decided    &  $\le 1$     &  =2          \\
                          & by detector state) &          &              \\
   $ |\cos\theta|$        & $<0.8$         & $<0.8$       & $<0.8$       \\
Track momentum            & $>0.5E_b$      &              & (0.5-1.15)$E_b$ \\
Track acollinearity   & $<10^{\circ}$  &              & $<10^{\circ}$ \\
$ \cos\theta_1 \times \cos\theta_2\dagger$
                          & $<0.02$        & $<0.001$     & $<0$          \\
Shower Energy             & (0.5-1.1)$E_b$ & $>0.5E_b$    & (0.1-0.35) GeV\\
Shower acoplanarity   & $>8^{\circ}$   & $<2^{\circ}$ & $>5^{\circ}$  \\
Vertex \& TOF             &                &              & $|t1-t2|<3$ ns \\
\hline \hline
\end{tabular}\\
$\dagger$ : $\cos\theta_1$ and $\cos\theta_2$ are the $\cos \theta$
values of the two tracks with the largest momentum; the selection on their 
product  is equivalent to a back-to-back requirement.
\end{table}

\subsection{Systematic uncertainty}\label{part1:xct_sun}

Typical luminosity measurements at BESI and BESII are summarized in
Table~\ref{lumbes}, where the uncertainties are around 2-3\%.
Comparative results from other experiments are collected in
Table~\ref{lumother}. To achieve the goal of the \bes3 experiment
to have better than $1\%$ precision, effects such as backgrounds, 
trigger efficiency, errors in the MC simulation, 
data-taking stability and radiative corrections must
 be considered. 
Since \bes3  has not yet started to take data,  our systematic
study is based on BESII and CLEOc experience
as well as \bes3 simulations.

\begin{table}[htb]
\caption{\label{lumbes}Luminosity measurement uncertainties
using  $e^+e^-$ final states at BESI and BESII. The online 
luminosity is  measured at small angles
while offline luminosity is measured with large angle Bhabha events in the
Barrel Shower Counter.}
\center
\begin{tabular}{c|cccc} \hline \hline
Energy region &  $J/\psi $    & $\psi^{\prime} $      & $\psi^{\prime
\prime} $      &  $R$-value   \\ \hline
Method        &  online      & offline      & offline       & offline      \\
Uncertainty   &  $ 6 \% $    & $3.2 \% $    & $1.83 \% $    &  $< 3 \% $   \\
Reference     &\cite{part1:jbberr} &\cite{part1:jbberr} &\cite{part1:ppbberr} &\cite{part1:rbberr} \\
\hline \hline
\end{tabular}
\end{table}

\begin{table}[htb]
\caption{\label{lumother}Luminosity errors from other experiments}
\center
\begin{tabular}{c|cccc} \hline \hline
Exp. Group &  $E_{c.m.} $ & Mode                & Error    & Ref.  \\ \hline
  CLEO     &  10 GeV      & $e^+e^-$, $\mu^+\mu^-$, $\gamma\gamma$ & $1.0 \%$ & \cite{part1:lumcleo} \\
DA$\Phi$NE &  1-3 GeV     & $e^+e^-$               & $0.6 \%$ & \cite{part1:lumdafne} \\
\hline \hline
\end{tabular}
\end{table}

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\subsubsection{Background analysis}

%e copy the background analysis in Ref. {\em verbatim et litteratim},
%since most of the part can similarly or directly used in the future
%\bes3 analyses.

Cosmic-rays usually dominate the background in the $\mu$-pair
sample. Tight track quality requirements minimize this contamination
with almost no loss in efficiency. The remaining cosmic ray background
can be estimated with two independent variables, impact parameter,
%(denoted as $d_{\pm}$ for positive or negative charge),
{\it i.e.}, the distance of closest approach to the beam-axis in
the plane transverse to the beam, and time-of-fight. At CLEOc the
background estimates determined by these techniques are 
$(0.5\pm0.1)\%$  and $(0.6\pm0.1)\%$,
respectively~\cite{part1:lumcleo}. 
According to a KORALB~\cite{part1:koralb} Monte Carlo study, 
background from $\tau$-pair decays is $0.07\%$, and
from $e^+e^- \mu^+\mu^-$ events~\cite{part1:grteemm} is $<0.002\%$.

The background in the photon-pair event sample
 from Bhabha events where both charged tracks are missed
is estimated to be $(0.1\pm0.1)\%$~\cite{part1:grteemm}.
For Bhabha events, 
$\tau$-pairs contribute 0.03\%, $e^+e^- e^+e^-$ final states
yield $(0.05\pm0.05)\%$ \cite{part1:grteeee}, and cosmic-rays are
estimated to be $(0.1\pm0.1)\%$.
The backgrounds estimated by CLEOc are at the 0.1\% 
level for all three background sources;
this is also what is expected at \bes3.

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\subsubsection{Trigger efficiency}\label{sxct_trig}

A two-level filtering technique is applied in the \bes3 data
acquisition system. The first level is the hardware trigger. The
second level  is a software trigger with special  algorithms
developed to select physics events
of different types~\cite{part1:fucdfilter}.

\begin{table}[htb]
\doublerulesep  2 pt \center \caption{\label{trigeff}Trigger
Efficiencies of \bes3 at $\sqrt{s}/2=1.89$ GeV.} \vskip 0.2cm
\begin{tabular}{ccccc} \hline \hline

 Event type &  $e^+e^-$            & $\mu^+\mu^-$              &
$\gamma\gamma$      \\ \hline
 Condition  & charge3           & charge1,2\&3       & common,neutralA\&B \\
 Level-1   &($99.95\pm 0.02)\%$  & $(92.2\pm 0.3)\%$   & $(99.78\pm 0.06)\%$ \\
 Level-2   &($99.999\pm 0.001)\%$& $(98.79\pm 0.06)\%$ & $(99.5\pm 0.3)\%$ \\
 Combined  &($99.95\pm 0.03)\%$  & $(91.1\pm 0.4)\%$   & $(98.9\pm 0.4)\%$ \\  \hline \hline
\end{tabular}
\end{table}
\noindent
The hardware trigger efficiencies are obtained using a method
similar to that of BESII~\cite{part1:trig,part1:trigref} and the online
software trigger efficiencies are given in Ref.~\cite{part1:fucdfilter}. 
The combined
results are summarized in Table~\ref{trigeff}.  A
conservative estimate of the uncertainty due to 
the trigger efficiency
is taken as 0.5\% for all three processes.

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\subsubsection{Monte Carlo simulation}

The uncertainty due to Monte Carlo simulation can be analyzed by
comparing the data distributions with those from MC simulation.
Many different methods have been proposed to qualify the
difference~\cite{part1:lumcleo,part1:lumdafne}. We consider the method 
used in Ref.~\cite{part1:lumdafne} to be reasonable and 
will adopt it for use in \bes3.

\subsubsection{ Stability }
Since the detector environment will change during the running 
period, the measured luminosity may not be stable, even after
calibration.  This was checked by CLEO, BES and DA$\Phi$NE and no
obvious influence on the luminosity measurement was observed. Hence, no 
error is assigned for 
this for now.

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\subsubsection{Theoretical accuracy}
The theoretical accuracy is actually constrained by the accuracy of the 
ISR calculation.
In the CLEOc analysis, radiative photons are generated
above some photon energy cutoff $k_0=E_{\gamma}/E_b$, and all
diagrams with softer photons are subsumed into the two body final
state. Two generators were used for $e^+e^-$ and $\mu^+\mu^-$ scattering, and
one for $\gamma\gamma$ events. The BK$ee$ program~\cite{part1:berendk} generates
$e^+e^-$ final states with zero or one radiative photon, yielding a
cross section that is accurate to the order of $\alpha^3$. Higher-order
corrections are available in the Bhlumi program~\cite{part1:sjadach},
which uses Yennie-Frautschi-Suura exponentiation to generate
multiple photons per event and yields a cross section with an
accuracy to the order of $\alpha^4ln^2(|t|/m_e^2)$, where $t$ is the typical
momentum-transfer. Similar to BK$ee$, the BK$\gamma\gamma$~\cite{part1:berendka}
and BKJ~\cite{part1:berendkj} Monte Carlo programs generate events with up
to one radiative photon and yields an order-$\alpha^3$ cross section
for $\gamma\gamma$ and $\mu$-pair respectively. Up to three radiative photons
in $\mu^+\mu^-$ events are possible (two from initial state radiation and
one from final state radiation) with FPAIR~\cite{part1:berendv}, which has
an order-$\alpha^4$ cross section accuracy. A photon cutoff of
$k_0=0.01$ is used for BK$ee$, BK$\gamma\gamma$, and BKJ, and $k_0=0.001$ for
Bhlumi and FPAIR. The generators used in the CLEOc analysis and the
predicted cross sections at $E_b=5.29$ GeV are listed in
Table~\ref{grtlum}.

\begin{table}[htb]
\caption{\label{grtlum}Generators for $e^+e^-$, $\gamma\gamma$, and $\mu^+\mu^-$ final
states.} \center
\begin{tabular}{l|ccc} \hline \hline
    Item             & $e^+e^-$          & $\gamma\gamma$          & $\mu^+\mu^-$        \\ \hline
\multicolumn{4}{c}{ CLEOc: cross section at $E_b$=5.29 GeV }
\\ \hline
$\alpha^3$ generator & BK$ee$         & BK$\gamma\gamma$        & BKJ             \\
cross section (nb)   & $8.45\pm 0.02$ &$1.124\pm 0.002$&$0.429\pm 0.001$ \\ \hline
$\alpha^4$ generator & BHLUMI         &                & FPAIR           \\
cross section (nb)   & $8.34\pm 0.02$ & $-$            &$0.427\pm 0.001$ \\ \hline
%$\Delta(\alpha^4 \& \alpha^3)$
%                     & $-1.3\%$       & $[-1.3\%]$     &$0.5\%$          \\ \hline
\multicolumn{4}{c}{ BESII: suitable for any energy region }
\\ \hline
$\alpha^3$ generator &  Radee         & Radgg          & Radmu \\
\hline
\multicolumn{4}{c}{ \bes3: suitable for any energy region }
\\ \hline

$\alpha^4$ generator & \multicolumn{3}{c}{ KKMC, Babayaga } \\
\hline \hline

\multicolumn{4}{c}{ DA$\Phi$NE: test at 1 GeV $<\sqrt{s}<$ 3 GeV }
\\ \hline
$\alpha^3$ generator &  Bhagenf       &                &     \\
                     &$\sigma_{\rm eff}(1.0195\mbox{GeV})=(430.7 \pm 0.3)$ nb &  &   \\ 
                     &  Mcgpj         &                &     \\
                     &  Bhwide        &                &     \\
$\alpha^4$ generator &  Babayaga      &                &     \\
                     &$\sigma_{\rm eff}(1.0195\mbox{GeV})=(431.0 \pm 0.3)$ nb &  &   \\
\hline\hline
\end{tabular}
\end{table}


Another check to ensure the correctness of theoretical calculations
is to compare the results from different generators. At DA$\Phi$NE,
the event generators \texttt{Babayaga}~\cite{part1:Calame2000,part1:Calame2001}
and \texttt{Bhagenf}~\cite{part1:Drago1997}, both developed for large 
angle Bhabha scatterings and based on the cross section calculation
in Ref.~\cite{part1:berendk}, have been %interfaced with the detector simulation
%program \texttt{GEANFI}~\cite{part1:Ambrosino2004} for evaluating the
evaluated, as well as their systematic uncertainties. The cross
sections calculated with the two generators, including the event
reconstruction efficiency, are listed in Table~\ref{grtlum}.

%\[ \mathtt{Babayaga} \quad \sigma_{\rm eff} = (431.0 \pm 0.3) \
% \mathrm{nb} \]
%\[ \mathtt{Bhagenf} \quad \sigma_{\rm eff} = (430.7 \pm 0.3) \
% \mathrm{nb} \]
The error given in the cross section is mainly due to the
Monte Carlo statistics. The theoretical uncertainty claimed by the
authors is 0.5\% in both cases. The radiative corrections due to the
treatment of initial and final state radiation in \texttt{Bhagenf}
and \texttt{Babayaga} have been compared with two other event
generators: \texttt{Bhwide}~\cite{part1:bhwide} developed for LEP
and \texttt{Mcgpj}~\cite{part1:Fedotovich:2003ww} developed for VEPP-2M,
which are all based on the cross section calculated in
Ref.~\cite{part1:Arbuzov:1997pj}. In Ref.~\cite{part1:KLOEnote} a detailed
comparison has been performed and the agreement is within 0.5\%,
supporting the claims from the authors of the \texttt{Bhagenf}
and \texttt{Babayaga} generators.

At BESII, generators with cross section accuracy
up to order-$\alpha^3$ are used. At \bes3, a generic Monte Carlo generator
KKMC~\cite{part1:kkmcpaper} has been adopted; this can provide cross
sections with an accuracy up to order-$\alpha^4$. Further checks,
such as the shape of the photon energy spectrum, can be made when 
data are available.

\subsection{Summary}\label{part1:xct_sum}

Table~\ref{errlum} summarizes the errors in the luminosity
measurement at CLEO~\cite{part1:lumcleo} and estimated errors for \bes3.
Improvements at \bes3 includes:
\begin{itemize}
\item Statistics : the 0.2\% statistical uncertainty corresponds to 
250,000 Monte Carlo events:  1,000,000 events will accommodate a
statistical uncertainty at the level of 0.1\%, which can be easily 
realized at \bes3;
\item Backgrounds : The same level of background as seen at CLEO, namely 
0.1\%, is expected at \bes3;
\item Trigger efficiency : as discussed in Sect.~\ref{sxct_trig}, this
uncertainty can be conservatively taken to be 0.5\%; 
%%%shall be less than 0.5\%;
\item consistency between data and Monte Carlo: 1.0 \% ;
\item radiative corrections : 0.5\%.
\end{itemize}

\begin{table}[htb]
\caption{\label{errlum}Relative Error (\%) in luminosity for
CLEO and \bes3.}
\center
\begin{tabular}{c|ccc|ccc} \hline \hline
Exp.Group             &\multicolumn{3}{c|}{CLEO}& \multicolumn{3}{c}{BES} \\ \hline
Source                &$e^+e^-$  &$\gamma\gamma$   &$\mu^+\mu^-$  &$e^+e^-$
&$\gamma\gamma$
&$\mu^+\mu^-$  \\ \hline
Monte Carlo Statistic & 0. 2  &  0. 2  & 0. 2  & 0. 1  &  0. 1  & 0. 1  \\
Backgrounds           & 0. 1  &  0. 1  & 0. 1  & 0. 1  &  0. 1  & 0. 1  \\
Trigger Efficiency    & 0. 5  &  0. 1  & 1. 3  & 0. 5  &  0. 5  & 0. 5  \\
Detector Modeling     & 1. 1  &  0. 9  & 1. 4  & 1. 0  &  1. 0  & 1. 0  \\
Radiative Corrections & 1. 3  &  1. 3  & 1. 0  & 0. 5  &  0. 5  & 0. 5  \\
Summed in Quadrature  & 1. 8  &  1. 6  & 2. 2  & 1. 3  &  1. 3  & 1.
3
\\ \hline
combine               &\multicolumn{3}{c|}{1.1\%}& \multicolumn{3}{c}{0.8\%} \\
\hline \hline
\end{tabular}
\end{table}