
%\section{Introduction}%%\footnote{By T.Barnes}
%%\section{Issues for BESIII\footnote{By S.L. Olsen}}

\section[Issues for \bes3]
{Issues for \bes3\footnote{By S.L. Olsen}}


\bes3 is well suited to address the remaining experimental questions
that are related to the low-mass ({\it i.e.} below open-charm
threshold) charmonium spectrum.  These include
precise determinations of the masses and widths of the $\etac$
and $\etacp$, and the relation of
the $\hc$ mass relative to the center-of-gravity mass of the
$\chi_{cJ}$ states.  In addition, we advocate a precision 
measurement of the partial width $\Gamma(\jpsi\rt\gamma\etac)$. 

\subsection{Measurements related to the $\etac$}

Although the $\etac$ is the ground  state $c\bar{c}$ meson and, 
in some sense,  the most fundamental of the charmonium mesons, 
its properties  are very poorly understood,
both theoretically and experimentally.  

\subsubsection{Mass of the $\etac$}
In spite of the
fact that the PDG lists more than 20 measurements of the $\etac$
mass~\cite{ted_PDG2006}, the world average value, 
$2979.8\pm 1.2$~MeV has a precision
that is poorer, by an order-of-magnitude or more than the
listed mass values for the $\jpsi$, $\psp$, $h_c$, $\chi_{c1}$ or
$\chi_{c2}$.  The agreement between different measurements is poor;
the PDG group's fit to the measured values has a confidence level of
0.6\% (see Fig.~\ref{fig:etac_M_G_PDG}).  Moreover, the mass value
itself is somewhat mysterious.  From 
Eqn.~\ref{eqn:spin-dependent},
the potential model expectation for the $\jpsi$-$\etac$ mass splitting is
\be
M(\jpsi) - M(\etac) =
\frac{32\pi\alpha_s(m_c)}{9 m^2_c}|\Psi(0)|^2,
\ee
where $|\Psi(0)|$, the wave function at the origin,
can be determined from the $\jpsi\ra e^+e^-$ partial
width via
\be
\Gamma(\jpsi\ra e^+e^-) =
\frac{16\pi\alpha^2 q^2_c|\Psi(0)|^2}{M^2_{\jpsi}}
(1 - \frac{16\alpha_s}{3\pi} + ...).
\ee
Using the world average value
$\Gamma(\jpsi\ra e^+e^-) = 5.55\pm0.14$~keV,
$\alpha_s(M^2_{\jpsi})\simeq 0.33$,
and $m_c\simeq M_{\jpsi}/2$, we find a
prediction for the mass splitting of
$M(\jpsi)-M(\etac)\sim 60$~MeV, which is about
half the measured value of $116.5\pm 1.2$~MeV.
This discrepancy is also seen in lattice QCD 
calculations~\cite{choe:2003slo}.

\begin{figure}[htbp]
%%\vskip 0.5cm
\centerline{
\includegraphics[width=14cm,angle=0,clip=]{./Part4/spectroscopy/etac_M_G_PDG.eps}
}  
\caption{
The distribution of measurements of the $\eta_c$ mass (left)
and width (right) from PDG-2006.}  
\label{fig:etac_M_G_PDG}
\end{figure}

\subsubsection{Width of the $\etac$}
The experimental situation on the $\eta_c$ total width is even more
confused.  The right panel of Fig.~\ref{fig:etac_M_G_PDG} shows
the range of $\eta_c$ total width measurements listed in the PDG
ables.  The PDG fit for a world average value of
$\Gamma = 26.5\pm 3.5$~MeV has a confidence level of only 0.1\%,
and, so, the errors on the measurements going into
the averaging process are scaled by a factor of 2.1. Here
there is 
a notable discrepancy between measurements using $\etac$ mesons
produced from the radiative decay $\jpsi\ra\gamma\etac$, which
tend to give low values, and those where the $\etac$ is produced
directly by two-photons, {\it i.e.} $\gamma\gamma\ra\etac$, or
in $B$ mesons decays via $B\ra K\etac$, which give higher values.

\subsubsection{The $\Gamma(\psi\rt\gamma\etac)$ partial width} 

In the potential model, radiative decays of the $\jpsi$ 
and $\psip$ to the $\etac$ states, 
{\it i.e.,} $\psi(nS)\rt\gamma\eta_c(n'S)$, 
proceed primarily via magnetic dipole (M1) 
transitions, with an amplitude given by
\be
\Gamma(\psi(nS)\ra \gamma \eta_c(n'S)) =
\frac{4}{3}\alpha q^2_c\frac{k^3_{\gamma}}{m^2_c}\vert \int dr~r^2~
R_{n^{\prime}0}(r)R_{n0}(r)~j_0(\frac{k_{\gamma}r}{2})\vert^2 .
\label{fig:M1_width}
\ee
Here $q_c$ and $m_c$ are the charge and mass of the $c$-quark
and $k_{\gamma}$ is the transition photon energy.  For
$\jpsi\rt\gamma\etac$, $n=n'=1$ and, in the limit of
zero recoil momentum, {\it i.e.} $k_{\gamma}r\simeq 0$, the
overlap integral is unity and the $\etac$ line shape is
modulated by a factor of $k^3_{\gamma}$. 

Taking $m_c=M_{\jpsi}/2$ and using  the PDG world
average values for the $\etac$ mass and $\jpsi$ 
mass and total width,
we determine the predicted partial width value from 
Eqn.~\ref{fig:M1_width} to be
\be
\Gamma(\jpsi\rt\gamma\etac) = 2.90 ~ {\rm keV~~~~Prediction},
\ee
which would correspond to the branching fraction
${\mathcal B}(\Gamma(\jpsi\rt\gamma\etac) = 3.1\%$.
The PDG value for this branching fraction
is based solely on a single measurement from
the Crystal Ball group~\cite{xtal-ball_gaiser:1986slo} and is 
${\mathcal B}(\Gamma(\jpsi\rt\gamma\etac) = 1.3\pm 0.4\%$.
The corresponding partial width is
\be
\Gamma(\jpsi\rt\gamma\etac) = 1.2\pm 0.4~{\rm keV~~~~Crystal~Ball~ 
measurement},
\ee
which is far below the predicted value.

This very dramatic discrepancy between potential model predictions
and the measured value of the $\jpsi\rt\gamma\etac$ partial width
makes it urgent that \bes3 remeasure this quantity 
reliably and with high precision.   In addition to its obvious
theoretical significance, such a measurement has important engineering
consequences.  The extraction of all $\etac$ branching fraction 
determinations that use $\etac$ mesons produced by the 
$\jpsi\rt\gamma\etac$ process (as is the case for most
of the $\etac$ branching fraction measurements listed
in the PDG) rely on this measurement.


\subsubsection{Experimental considerations}

With a sample of  $\sim 10^{9}$ $\jpsi$ events accumulated
at the resonance peak, we can expect many thousands of detected
$\gamma\etac$ events for each of the dominant $\etac$
decay modes.  This will provide the opportunity to measure
the mass and width in each mode with a statistical precision that is
about and order-of-magnitude better than the current world averages. 
Since the effects of interference between the $\etac$ amplitude 
and that for possible coherent continuum production of
the same final state will be an
important source of systematic error,  the measurements should
be done using as many different $\etac$ decay modes as possible.  

Additional data accumulated at the peak of the $\psip$ would
be very useful.  The transition gamma-ray energies for the
$E1$ decays $\psip\rt\gamma\chi_{c2}$ and $\psip\rt\gamma\chi_{c1}$, 
namely $127.60\pm0.09$~MeV and $166.07 \pm 0.08$~MeV, respectively, 
are very similar to that of the gamma in $\jpsi\rt\gamma\etac$ 
and, thanks to precision measurements from Fermilab 
experiment E835~\cite{andreotti:2005slo}, these energy values
are very well known.  Moreover,  the $\chi_{c1,2}$ and the $\etac$ 
have many decay final states in common and with similar
branching fractions.   Therefore, since the $\chi_{c1,2}$ states 
are narrow and the branching fractions for $\psip\rt\gamma\chi_{c1,2}$
are larger than that for $\jpsi\rt\gamma\etac$, a sample of
$\sim 10^{8}$ events taken at the $\psip$ peak will allow for
measurements of these two calibration channels that would have 
precision levels comparable to those
of the $\etac$ measurements with the same final state, 
made with $\sim 10^{9}$ $\jpsi$ events. 
Such complementary measurements would be useful for
controlling the experimental systematic
effects to levels that are smaller than the statistical errors.


For the $\psip\rt\gamma\etac$ transition, $n=2$ and $n^{\prime}=1$,
the radial wave functions in Eqn.~\ref{fig:M1_width} are different
and the $\etac$ recoil momentum is not small.   In
this case, the the line shape is modulated by an {\it additional}, 
model-dependent factor that the CLEO group estimated to
be $\sim k^4_{\gamma}$~\cite{slo_cleoc_psip2gammaetac}.  Therefore,
although $\psip$ data will provide checks and calibrations
for measurements done with $\jpsi$ data,
this strong,  model-dependent modulation of the line shape 
probably precludes using  the $\psp\rt\gamma\etac$
data itself to make precise model-independent measurements of the
 mass and width of the $\etac$.

The ${\mathcal B}(\jpsi\rt\gamma\etac)$ measurement has to
be done inclusively, {\it i.e.}, the $\etac$ signal has to
be measured from the $E_{\gamma}\simeq 114$~MeV peak 
in the inclusive photon spectrum, independently (as much as possible) 
of any specific $\etac$ decay mode.  Since the Crystal Ball
group was able to identify and measure such a peak, this
should be doable in \bes3, where the electromagnetic
calorimeter has better granulatity and a factor-of-two better
gamma-ray energy resolution.  A difficulty here is 
that the low energy of the transition gamma makes it
not useful as an event trigger.  For $\jpsi$ running,
trigger conditions have to be established that insure all
significant $\etac$ decay modes satisfy them with high
efficiency.   

Trigger biases can be avoided by using tagged $\jpsi$
events from the $\pi^+\pi^-\jpsi$ decays of the $\psip$
that are triggered only by the tracks of the transition
$\pi^+\pi^-$ pair.  With a 
$\sim 10^{8}$ event sample taken at the peak of the $\psip$
resonance, we can expect about $\sim 10^{7}$ tagged $\jpsi$
decays, including nearly $10^{5}$ with monochromatic
gammas from the $\jpsi\rt\gamma\etac$ transition
detected in the electromagnetic calorimeter.

\subsection{Mass and width of the $\etacp$}

Among the below-threshold charmonium states,
the $\etacp$ meson has the most poorly measured mass and width.
The PDG average for the mass, $3637\pm 4$~MeV, has a fit confidence
level of 2.1\%.  The average width value, based on two measurements,
is $14\pm 7$~MeV.

At \bes3, $\etacp$ mesons will be produced during $\psip$ running 
via the radiative M1 decay $\psp\rt \gamma\etacp$. According to
the relation given in Eqn.~\ref{fig:M1_width}, the partial width   
$\Gamma(\psp \ra \gamma \etacp)$ can be estimated by   
scaling the measured the measured partial width for $\jpsi \ra\gamma\etac$
($1.19 \pm 0.34$~keV by $k^{\prime 3}_{\gamma}/k^3_{\gamma}$, where
$k^{\prime}_{\gamma} = 48 \pm 4$~MeV ($k_{\gamma}= 114.3 \pm 1.2$~MeV) is 
gamma energy
for the $\psp \gamma\etacp$ ($\jpsi \gamma\etac$) transition.  This
gives an expected partial width
$\Gamma(\psp\ra\gamma\etacp)=87\pm 25$~eV, and branching fraction
${\mathcal B}(\psp\ra \gamma\etacp) = (2.6 \pm 0.7)\times 10^{-4}$.
Thus, the expected $\etap$ mesons production rate in \bes3 
will be low and, because of the low energy of
the transition gamma ray,  detection
will be difficult.  Precise $\etacp$ mass and width measurements   
will be a challenge for \bes3.


\subsection{The $\hc$ mass}

The $\hc$ meson was observed
by CLEO in both inclusive and exclusive processes.  In the 
inclusive process $\psp\ra\pi^0\hc$ the $\hc$ decay products
are not detected and the signal is a
distinct peak in the $\pi^0$ recoil mass distribution.
Figure~\ref{fig:hc_CLEO} shows the very clean signal seen by CLEO 
for the exclusive process $\psp\ra\pi^0\hc$ with 
$\hc\rt\gamma\etac$~\cite{part4_CLEO-ch_c05}.
Evidence for the $\hc$ was also reported by Fermilab experiment E835 in the process
$\bar{p}p\ra\hc\ra\gamma\etac\ra\gamma\gamma\gamma$~\cite{part4_E835}.
CLEO measures $M(\hc)=3525.35\pm0.27\pm0.2$~MeV; E835
reports $3525.8\pm 0.2 \pm 0.2$~MeV.

\begin{figure}[htbp]
%%\vskip 0.5cm
\centerline{
\includegraphics[width=9cm,angle=0,clip=]{./Part4/spectroscopy/hc_excl_CLEO.eps}
}  
\caption{\label{fig:hc_CLEO}
The exclusive signal for $\psp\ra\pi^0 h_c$; $h_c\ra \gamma\etac$
from CLEO.
}
\end{figure}


Naively, if the radial dependence of the
$\vec {\S}_c \cdot \vec {\S}_{\bar c}$ term   
in Eq.~\ref{eqn:spin-dependent} is
truly a $\delta$-function, one would expect the mass
of the $\hc$ to be equal to the
center-of-gravity mass of the $\chi_{cJ}$ states:
\be
M_{c.o.g.}(\chi_{c}) = \frac{1}{9}(M(\chi_{c0})
+ 3M(\chi_{c1}) + 5M(\chi_{c2}))= 3525.30\pm 0.08~{\rm MeV},
\ee
where PDG masses for the $\chi_{cJ}$ states are used.
A more detailed calculation~\cite{part4_CO}, discussed
below in Sect.~\ref{sec:transition_hadron_hc}, predicts the mass
to be a few MeV below $M_{c.o.g.}(\chi_c)$.
The $M(\hc)$ measurements seem to prefer the naive
expectations.  However, the current precision 
leaves room for at least a factor of two
improvement from \bes3.  The cleanliness of the
CLEOc $h_c$ signal in the exclusive decay channel
(see Fig.~\ref{fig:hc_CLEO}) indicates that improved
statistics afforded by the large $\psip$ sample expected 
for \bes3 will result in a commensurate improvement
in the precision of the $h_c$  mass measurement.

