
%%\section[Monte Carlo Simulation of Spin-singlet Charmonium]
%%{Monte Carlo Simulation of Spin-singlet Charmonium~\footnote{By
%%Haixuan Chen}}

\subsection{$\psip\to\gamma\etac,\etac\to K^0_S K \pi$}

Using the BESIII Offline Software System (BOSS), a data sample of
about 150,000 Monte Carlo simulated 
$\psip\to\gamma\etac,\etac\to K^0_S K^{\pm} \pi^{\mp}$  
events has been analyzed. In order to extract
the $\etac$ signal, two charged tracks with net
charge zero and originating from the interaction region plus a 
$K_S \to \pi^+\pi^-$ decay with a
reconstructed secondary vertex are required. The photon
candidate with highest energy is regarded as the radiative photon
from the $\psip$. The $K_S$ selection includes the
requirements $m_{K_S} \in
[0.44,0.56]~\hbox{GeV}/c^2$ and $\cos \theta > 0.9$,
where $\theta$ is the angle between the radiative photon and the
PMISS direction of the $\etac\to K^0_S K \pi$ candidate. 
Figure~\ref{mkskpi_etac}
shows the $K_S K\pi$ invariant mass distribution, where the
$\etac$ signal is evident; a fit gives a mass resolution value of
$(6.78\pm0.05)~\hbox{MeV}/c^2$.  The output value of $m_{\etac}$
from the fit to the reconstructed $M_{K_S K \pi}$ peak is $2979.94\pm 0.06
~\hbox{MeV}/c^2$.   The difference from the input mass is $\triangle m_{\etac} =
(0.14\pm0.06)~\hbox{MeV}/c^2$, thereby
demonstrating that $m_{\etac}$ can be correctly reconstructed in
this channel.  The detection efficiency based on these event selection
requirements is $(14.60\pm0.07)\%$,  where uniform angular distributions
are assumed. The detection efficiency is presumed to be smaller if 
more realistic angular distributions are considered. 
Using the branching fractions
of $\psip\to\gamma\etac$ and $\etac\to K^0_S K^{\pm}
\pi^{\mp}$~\cite{ted_PDG2006}, and assuming a detection efficiency of
$10\%$,  $1800$  $\etac$ signal signal events are expected to be observed
in a $3\times 10^{8}$ $\psip$ event sample (which could be collected within
about 0.1 year of BESIII operation).

\begin{figure}[htbp]
\centerline{\psfig{file=./Part4/transition/chenhx/eps/mKsKPi_getac_psip_1.eps,width=8.0cm}}
\caption{The $K_S K\pi$ nvariant mass distribution in the
$\etac$ mass region. The distribution is fitted using a double
Gaussian function.}
\end{figure}\label{mkskpi_etac}

\subsection{$\psip\to\gamma\etacp,\etacp\to K^0_S K \pi$}

About 150,000 Monte Carlo simulated 
$\psip\to\gamma\etacp,\etacp\to K^0_S K^{\pm} \pi^{\mp}$ events are
analyzed.  The same selection criteria as those used in analysis of
$\psip\to\gamma\etac$ are applied to the reconstructed data and 
the resulting $K_S K\pi$ invariant mass distribution is shown in
Fig.~\ref{mkskpi_etacp}.  An $\etacp$ signal with a
mass resolution of $(9.64\pm 0.11)~\hbox{MeV}/c^2$ is evident. 
The output value of $m_{\etacp}$ from a fit is $3628.41\pm 0.11
~\hbox{MeV}/c^2$, which corresponds to an input-output mass
difference of  $\triangle m_{\etacp} =(0.41\pm0.11)~\hbox{MeV}/c^2$.
This means that $m_{\etacp}$ can also be reconstructed correctly. The 
detection efficiency  based on these event selection criteria
is $(8.03\pm0.11)\%$ where uniform angular distributions are assumed. 
The detection efficiency is expected to be smaller for more realistic angular
distributions.  Assuming a detection efficiency of
$5\%$, about $900$ $\etacp\to K_S K\pi$ signal events are expected to be
observed in a $3\times 10^{9}$ $\psip$ event sample.


\begin{figure}[htbp]
\centerline{\psfig{file=./Part4/transition/chenhx/eps/mKsKPi_getacp_psip_1.eps,width=8.0cm}}
\caption{The $K_S K\pi$ invariant mass distribution in the
$\etacp$ mass region. The distribution is fitted with a double
Gaussian.}
\end{figure}\label{mkskpi_etacp}



\subsection{$\psip\to\pi^0 h_c,h_c\to \gamma\etac, \etac\to K^0_S K
\pi$}

About 50,000 Monte Carlo simulated events of the type 
$\psip\to\pi^0 h_c,h_c\to \gamma\etac, \etac\to K^0_S K^{\pm} \pi^{\mp}$ 
are analyzed. For the event selection, two charged tracks with net charge
zero and originating from the interaction region plus a $K_S\to\pi^+\pi^-$
candidate with a reconstructed secondary vertex are required. At least three
photon candidates are required in each event and the photon
candidate with highest energy is regarded as the radiative photon
from the $h_c\to\etac$ transition.  The two-photon combination with smallest
$|m_{\gamma\gamma}-m_{\pi^0}|$ value are regarded as the candidate
$\pi^0$. The $K_S$ selection includes the requirement $m_{K_S} \in
[0.44,0.56]~\hbox{GeV}/c^2$. The $\etac\to K_S K \pi$ signal requirements
are $m_{K_S K \pi} \in [2.6,3.4]~\hbox{GeV}/c^2$ and $\cos \theta >
0.95$, where $\theta$ is the angle between the
radiative photon from the $h_c\to\gamma\etac$ 
decay and the PMISS direction of the 
candidate $\etac\to K^0_S K \pi$ track combination. 
The resulting invariant mass distribution of  $\gamma K_S K\pi$
is shown in Fig.~\ref{mgkskpi_hc}. An $h_c$ signal is
observed with a resolution of $(11.3\pm
0.6)~\hbox{MeV}/c^2$. The output value of $m_{h_c}$ from the
fit to the peak is $3528.1\pm 0.7 ~\hbox{MeV}/c^2$, which
corresponds to an input-output difference of
$\triangle m_{h_c} = (2.0\pm0.7)~\hbox{MeV}/c^2$.
This indicates that $m_{h_c}$ is not
reconstructed perfectly in this mode, presumably
because of the presence of three 
relatively low energy photons. 
A possible reason is that the current version of BOSS's
modeling and reconstruction of the photon energy is 
not very accurate and this results
in a systematic error in the final result.
The detection efficiency for these event selection criteria is
$(8.71\pm0.33)\%$, where uniform angular distributions are assumed. 
The detection efficiency is expected to be smaller for more realistic angular
distributions.  Assuming a detection efficiency of
$5\%$, an $h_c \to\gamma\etac$, $\etac\to K_S K\pi$ signal of about 
$450$ detected events  is expected in a
$3\times 10^{9}$ $\psip$ event sample.


\begin{figure}[htbp]
\centerline{\psfig{file=./Part4/transition/chenhx/eps/mGKsKPi_pi0hc_psip_1.eps,width=8.0cm}}
\caption{Invariant mass distribution of $M_{\gamma K_S K \pi}$ in
the $h_c$ mass region. The distribution is fitted using a CB
function plus double Gaussian.}
\end{figure}\label{mgkskpi_hc}
