\chapter[$\tau$ mass near threshold]{$\tau$ mass near
threshold\footnote{By Xiao-Hu Mo, Y.~K. Wang, C.~Z.~Yuan and C.~D.~Fu}}
\label{part6:sec:tau_mass}

%%%%% four triangles
\newsavebox{\talupright}
\savebox{\talupright}(0,0){%
\setlength{\unitlength}{0.5mm}
\linethickness{0.2mm}
\put(0,0){\line(1,0){10.0}}
\put(0,0){\line(0,1){10.0}}
\put(0,10){\line(1,-1){10.0}}
}
\newsavebox{\talupleft}
\savebox{\talupleft}(0,0){%
\setlength{\unitlength}{0.5mm}
\linethickness{0.2mm}
\put(0,0){\line(1,0){10.0}}
\put(10,0){\line(0,1){10.0}}
\put(0,0){\line(1,1){10.0}}
}
\newsavebox{\taldwright}
\savebox{\taldwright}(0,0){%
\setlength{\unitlength}{0.5mm}
\linethickness{0.2mm}
\put(0,10){\line(1,0){10.0}}
\put(0,0){\line(0,1){10.0}}
\put(0,0){\line(1,1){10.0}}
}
\newsavebox{\taldwleft}
\savebox{\taldwleft}(0,0){%
\setlength{\unitlength}{0.5mm}
\linethickness{0.2mm}
\put(0,10){\line(1,0){10.0}}
\put(10,0){\line(0,1){10.0}}
\put(10,0){\line(-1,1){10.0}}
}

\section{Introduction}
\label{part6:xct_int}
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
The mass of the $\tau$ lepton is a fundamental parameter of the Standard
Model; many 
experiments~\cite{part6_taudasp,part6_tauspec,part6_taumak2,part6_taudelco,
part6_tauargus,part6_taubes,part6_taucleo,part6_tauopal,part6_taubelle,part6_taukedr}
have measured it as shown in Fig.~\ref{taumm}. Experimentally, 
the depolarization technique  developed by the KEDR collaboration 
has been used to realize a highly accurate beam energy 
calibration --- at the level of one part in $10^{6}$ for c.m. 
energies near the
$\tau$ mass threshold~\cite{part6_Bogomyagkov}--- while theoretically,
accurate calculations have claimed precisions
at the level of one part in $10^{4}$ 
for the near-threshold $\tau$-pair production 
cross section~\cite{part6_voloshin,part6_smith,part6_pich,part6_ruizf}. 
Large $\tau$-pair  data samples are expected at \bes3 and,
therefore, it is of great interest to understand how
accurate a $\tau$ mass measurement we can look forward 
to having in the near future.

\begin{figure}[tbh]
\begin{center}
\includegraphics[height=7cm,width=10.cm]{./Part6/figures/taush.eps}
\caption{\label{taumm}A comparison of  different measurements of
the $\tau$ mass. The vertical line indicates the current world average value:
$1776.99^{+0.29}_{-0.26}$ MeV~\cite{pich_PDG}, which is the averaged result
of the measurements from
Refs.~\cite{part6_taudelco,part6_tauargus,part6_taubes,part6_taucleo,part6_tauopal}.}
\end{center}
\end{figure}

%\begin{floatingfigure}[r]{5cm}
%\includegraphics[height=5cm,width=5.cm]{./Part6/figures/taush.eps}
%\caption{\label{taumm}Comparison of the different measurements of
%the $\tau$ mass.}
%\end{floatingfigure}
%

Usually, either pseudomass and threshold-scan methods are employed to
measure the $\tau$ mass. The scan method adopted by the BES-I 
collaboration achieved the most accurate single
measurement of the $\tau$ mass~\cite{part6_taubes}: 
\beq m_{\tau} =
1776.96^{+0.18+0.25}_{-0.21-0.17} \mbox{ MeV }. \label{bestama} \eeq
Note that the relative statistical ($1.6\times 10^{-4}$) and
systematic ($1.7\times 10^{-4}$) uncertainties are comparable in
magnitude, improvements are needed in both categories.

\section{Statistical Optimization}
\label{part6:xct_stopt}
\subsection{Methodology}\label{sect_two}
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
We need to develop a scheme that provides the most precise $\tau$ mass 
measurement one can acheive given a specific period of data-taking time 
or, equivalently, a given amount of integrated luminosity.
A sampling technique 
is utilized to simulate various data taking possibilities, among which 
the optimal one is to be found. The likelihood function for a given scheme
is constructed as~\cite{part6_taubes,part6_taufirst,part6_tauxcold}:
\begin{equation}
LF(m_{\tau})=\prod\limits_i^n
\frac{\mu_i^{N_i} e^{-\mu_i} }{N_i!}~ ,
\label{lklihd}
\end{equation}
where $N_i$ is the observed number of $\TT$ events detected
in the  $e \mu$ final 
state\footnote{For simplicity only the $e \mu$ channel is considered 
at this time; the statistical significance will be improved if more 
channels are taken into account, see Sect.~\ref{sect_dis} for 
a detailed discussion.} at 
the c.m. energy scan point $i$ and $\mu_i$ is 
the expected number of events given by
\begin{equation}
 \mu_i(m_{\tau})=[\epsilon \cdot B_{e\mu} \cdot 
\sigma_{exp} (m_{\tau},E^i_{cm})+\sigma_{BG}] \cdot {\cal L}_i~~.
\label{mudef}
\end{equation}
In Eq.~\eref{mudef}, ${\cal L}_i$ is the integrated luminosity at 
$i^{\rm th}$ point, $\epsilon$ is the overall detection 
efficiency for the $e\mu$ final
states (including the trigger and event selection efficiencies), 
$B_{e\mu}$ is the combined branching ratio for 
decays $\tau^+ \rightarrow e^+ {\nu}_e \overline{\nu}_{\tau}$ and
$\tau^- \rightarrow \mu^- \overline{\nu}_{\mu} \nu_{\tau}$ (or
the corresponding charge conjugate mode) and $\sigma_{exp}$ is the
experimentally observed cross section, which has the form~\cite{part6_rad}
\begin{equation}
\sigma_{exp}
(s,m_{\tau},\Delta)=\int_{0}^{\infty}
d\sqrt{s'} G(\sqrt{s'},\sqrt{s})
\int_{0}^{ 1-\frac{ 4m_{\tau}^2 }{ s' } } dx
F(x,s') \frac{ \bar{\sigma}(s'(1-x),m_{\tau}) }{|1-\Pi (s'(1-x))|^2}~.
\label{expsec:1}
\end{equation}
Here $\sqrt{s}$ is the c.m. energy; $F(x,s)$ is the 
initial-state radiation factor~\cite{part6_rad}, $\Pi$ is the vacuum 
polarization factor~\cite{part6_ruizf,part6_berends,part6_rodrigo}, 
and $G(\sqrt{s'},\sqrt{s})$, which is usually treated as a
Gaussian distribution~\cite{part6_vitual}, depicts the energy 
spread of the $e^+e^-$ collider. The production cross section 
$\bar{\sigma}$ can be expressed as\footnote{
Here the Voloshin's formula in Ref.~\cite{part6_voloshin} is adopted. 
This takes  into account: (a) radiation from 
the initial electron and positron; (b) vacuum polarization of 
the time-like photon; (c) corrections to the special density 
of the electromagnetic current of the tau leptons; and (d)
the interference between the effects (a)-(c) which start 
from the relative order $\alpha^2$.} 
\begin{equation}
\bar{\sigma} (v) = \frac{2\pi\alpha^2}{3s}
 v(3-v^2)F_c(v)\left(1+\frac{\alpha}{\pi}S(v)-
\frac{\pi \alpha}{2v}+h(v)\right),
\label{prdsig}
\end{equation}
Here $v=\sqrt{1-4m_{\tau}^2/s}$ is the velocity of either of the 
$\tau$ leptons in the c.m. frame and $F_c(v)$ is the so-called Coulomb 
factor, which is defined as
\beq
F_c(v)=\frac{\pi\alpha/v}{1-\exp(-\pi\alpha/v)}~~.
\label{fcdef}
\eeq
A description of the correction function $S(v)$ can be found in 
Schwinger's textbook~\cite{part6_schwinger}:
\beq
\begin{array}{ll}
 S(v)=& {\displaystyle \frac{1}{v} \left\{ (1+v^2) \left[ \frac{\pi^2}{6}+
     \ln{ \left( \frac{1+v}{2} \right) }
     \ln{ \left( \frac{1+v}{1-v} \right) }
   +2\mbox{Li}_2 \left( \frac{1-v}{1+v} \right)
   +2\mbox{Li}_2 \left( \frac{1+v}{2} \right) \right. \right. }\\ \\
      & {\displaystyle \left. -2\mbox{Li}_2 \left( \frac{1-v}{2} \right)
       -4\mbox{Li}_2(v)+ \mbox{Li}_2(v^2) \right] }\\ \\
      & {\displaystyle  +\left[ \frac{11}{8}(1+v^2)-3v
       +\frac{1}{2}\frac{v^4}{(3-v^2)} \right]
       \ln{ \left( \frac{1+v}{1-v} \right) } }\\ \\
      & {\displaystyle \left. + 6v\ln \left( \frac{1+v}{2} \right)-4v\ln {v}
       +\frac{3}{4}v\frac{(5-3v^2)}{(3-v^2)} \right\} }~,
      \end{array}
\label{svdef}
\eeq
with
$$
 \mbox{Li}_2(x)=-\int^x_0\ln(1-t)dt/t=\sum \limits_{n=1}^\infty
   x^n/n^2.
$$
The correction function $h(v)$ is expressed in terms of a
double integral~\cite{part6_voloshin,part6_smith}:
\beq  h(v)=\frac{2\alpha}{3\pi} \left[
-2\lambda Im \int^{\infty}_{0}dt\int^{\infty}_{1}dx
  (\frac{1+t}{t})^{i\lambda}\frac{(t+izxv^{-1})^{i\lambda-1}}
   {(t+1+izxv^{-1})^{i\lambda+1}}(1+\frac{1}{2x^2})
   \frac{\sqrt{x^2-1}}{x^2} \right]~~,
\label{hvdef}
\eeq
with
$$ z=m_e/m_{\tau} \ \ , \ \ \lambda=\frac{\alpha}{2v}~.$$
The function $h(v)$ contains corrections from two sources:  
the so-called hard correction due to a finite radiative effect in 
the $\tau$ electromagnetic vertex at the threshold, 
and from the modification of the Coulomb interaction
due to running of the coupling $\alpha$, which is described by the
Uehling-Serber radiative correction to the potential~\cite{part6_uehling}. 

In the following study, we take $\epsilon=14.2\%$~\cite{part6_tauxc}, 
the c.m. energy spread\footnote{The c.m. energy 
spread is calculated from
the empircal formula:
$\Delta= (0.16203 E^2_{cm}/4+0.89638)\times 10^{-3}~\mbox{ GeV}$,
which gives $\Delta$ = 1.4 MeV at 
$E_{cm}$ = 1.77699 GeV~\cite{part6_tauxc}.} $\Delta = 1.4$~ MeV and
$B_{e\mu} = 0.06194$~\cite{pich_PDG}. We neglect the corresponding 
uncertainties, which are left for the systematic study. As for 
$\sigma_{BG}$, previous experience~\cite{part6_taufirst} indicates 
that $\sigma_{BG} \approx 0.024 \mbox{ pb}^{-1}$, which is small 
compared to the $\TT$ production cross section near threshold of
($\simeq0.1~{\rm nb}^{-1}$).  In any case, a large data sample
 can be taken below the threshold to determine $\sigma_{BG}$ accurately. 
For simplicity, we set 
$\sigma_{BG}$ to be zero, which means it is background free.
In fact, if $\sigma_{BG}$ is a constant, it has no effect on the 
optimization of the data taking strategy.  

Since we want to optimize the accuracy of 
the $m_{\tau}$ measurement, the value of $\tau$  mass itself is 
assumed to be known. In fact, the optimal number of points and the 
luminosity distribution among these points are correlated.
To resolve this dilemma, we use an iterative procedure:
we start from a simple distribution and
look for the optimal number of points; we then look for 
an optimal distribution; with such a distribution, we then reoptimize
the number of points.

\subsection{First Optimization}\label{sect_opone} 
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
As a starting point, we study an energy interval that
is evenly divided, {\it viz.}
\begin{equation}
E_i=E_0+i\times \delta E,\ \ \ \  (i=1,2,...,N_{pt}).
\label{engdiv}
\end{equation}
Here the initial point is $E_0=3.545~\mbox{GeV}$,
the final point is $E_f=3.595~\mbox{GeV}$ and the fixed step is
$\delta E=(E_f-E_0)/N_{pt}$, where $N_{pt}$ is the number of energy
points. The total luminosity is distributed equally 
(${\cal L}_i = {\cal L}_{tot}/N_{pt}$) at each point,\footnote{
Another scheme is to apportion the total number of events evenly at 
each point, the luminosity at each point is determined by
relation ${\cal L}_i = {\cal L}_{tot} / (\sigma_i \cdot \sum 1/\sigma_i)$
with $\sigma_i$ denotes the cross section at $i$-th point. 
This scheme leads to the same final conclusion of this study.} 
and the fitted $m_{\tau}$ and corresponding uncertainty 
$S_{m_\tau}^2(m_\tau) $ using Eq.~\eref{lklihd} is averaged 
over all the samplings ($N_{samp}$) for each $N_{pt}$ value
in order to suppress or reduce the statistical 
fluctuation~\cite{part6_dataanalysis}:
\begin{equation}
\overline{m}^i_\tau=\frac{1}{N_{samp}} \sum\limits_{j=1}^{N_{samp}}
m^i_{\tau j}\  , \label{mbar}
\end{equation}
\begin{equation}
S_{m_\tau}^2(m^i_\tau)=\frac{1}{N_{samp}-1}\sum\limits_{j=1}^{N_{samp}}
(m^i_{\tau j}-\overline{m}^i_{\tau })^2 \ . \label{smtau}
\end{equation}
Here $i$ indicates the  scheme being tested while $j$ indicates 
the sampling times, which is 500 in this study.

%%%\subsubsection{Data taking points}\label{ssect_dttk}
Using the experiment parameters $\epsilon$, $\Delta$, and $B_{e\mu}$
given in Sect.~\ref{sect_two}
and setting ${\cal L}_{tot}=30\mbox{ pb}^{-1}$,
we obtain the fitted results for
$N_{pt}$ ranging from 3 to 20 
shown in  Figs.~\ref{lmnpt}(a) and (b), 
where $\Delta m_\tau = \overline{m}_\tau - m^0_\tau$, the difference between
the average fitted $m_{\tau}$ and the input value ($m^0_\tau=1776.99$ MeV 
according to PDG06~\cite{pich_PDG}), and $S_{m_{\tau}}$ is the 
corresponding $rms$ uncertainty.

The $\Delta m_\tau$ values, shown as the dots in Fig.~\ref{lmnpt}(a), 
indicate the fit bias due to the limited number of 
events.  With increased luminosity (and increased 
number  of events), the bias tends to zero.  
This point is demonstrated more clearly in 
a separate study 
of the variation of  $\Delta m_\tau$ with luminosity,
discussed below (in reference to Table~\ref{lumauty}). 

For the fit uncertainties, $S_{m_{\tau}}$,  two points should be 
noted: first, $S_{m_{\tau}}$ is much larger than absolute value of
the bias $|\Delta m_\tau|$. Thus,  from the point view of accuracy, 
the optimization of the former is much more crucial 
than that of the latter.
Therefore, in the following study $S_{m_{\tau}}$ is used as the 
goodness-of-fit quantity. 
Second, it is evident in  Fig.~\ref{lmnpt}(b)
that taking very few data  points yields
a large uncertainty, while having many points makes no contribution
to the improvement of the accuracy.  From the figure one can
see that $N_{pt}=5$ is near the optimal number of
measurement points for the evenly-divided-distribution scheme.

\begin{figure}[htbp]
\begin{minipage}{6cm}
\includegraphics[height=5cm,width=6.cm]{./Part6/figures/direfixtotlumm.eps}
%(a) $\Delta m_\tau$ and $S_{m_\tau}$ against $N_{pt}$
\end{minipage}
\hskip 2cm
\begin{minipage}{6cm}
\includegraphics[height=5cm,width=6.cm]{./Part6/figures/direfixtotlumsm.eps}
%(b) $|\Delta m_\tau|$ and $S_{m_\tau}$ against $N_{pt}$
\end{minipage}
\caption{\label{lmnpt}The variation of $\Delta m_\tau$ 
(and $|\Delta m_\tau|$) 
and $S_{m_\tau}$ {\it versus} the number of 
measurement points ${N}_{pt}$. 
In (a) the dots and bars represent $\Delta m_\tau$ and 
$S_{m_\tau}$, respectively.
In (b) the diamonds denote $|\Delta m_\tau |$ and
the crosses $S_{m_\tau}$.}
\end{figure}

%%%\subsubsection{Optimal distribution}
With five points, we search further for ways to minimize the
fit uncertainty. Without any theoretical considerations, a sampling 
technique is employed and the energy points 
are distributed randomly over the chosen interval. 
In a total of 200 samplings, the one with the smallest uncertainty  
has $S_{m_\tau}=0.152$ MeV and the one with the greatest 
uncertainty has  $S_{m_\tau}=1.516$ MeV.
The two extreme distributions are indicated in Fig.~\ref{rdskn}. 
It is apparent that the small uncertainty measurement has scan
points that are crowded near the threshold,
while the scheme with the large uncertainty has
scan points that are far from the threshold.\footnote{
For both schemes, the lowest energy point in 
Fig.~\ref{rdskn} corresponds 
to an expected number of events of zero, since they are below 
threshold.} 
Intuitively, one expects that the smallest uncertainty occurs
at energies near the point where the derivative of the cross section 
is largest.  This must be, therefore, close to the optimal position for 
data taking, as discussed in the next section.

\begin{figure}
\begin{center}
\includegraphics[height=6cm,width=7.cm]
%{./Part6/figures/time200direrand5point.eps}
{./Part6/figures/rdskn.eps}
\caption{\label{rdskn}The distributions of the data taking points
for the schemes with the smallest (denoted by stars) and largest 
(denoted by diamonds) values of $S_{m_\tau}$. 
The solid curve is the calculated observed cross section,
and the dashed line the corresponding derivative of the cross section
with respect to energy (with a scale factor of $10^{-2}$).}
\end{center}  
\end{figure}

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\subsection{Second Optimization}\label{sect_optwo} 
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
Based on the previous study, we embark on studies to determine 
(a) the energy region most sensitive to the fit uncertainty, 
(b) the optimal number of points that should be taken in that region, 
and  (c) the locations of the optimal points. 

\subsubsection{Optimal region}
To hunt for the most sensitive energy region, two regions are defined 
as shown in Fig.~\ref{regdy}(a):
region $I$ ($E_{cm} \subset (3.553,~3.558)~\mbox{GeV}$ ), where
the derivative is greater than 75\% of its maxinum value and
region $II$ ($E_{cm} \subset (3.565,~3.595)~\mbox{GeV}$ ), where
the variation of the derivative is smoother than it is in region $I$.

\begin{figure}[htbp]
\begin{center}
\begin{minipage}{6cm}
\includegraphics[height=5cm,width=6.cm]{./Part6/figures/deri2reg.eps}
(a) Energy regions $I$ and $II$
\end{minipage}
\hskip 2cm
\begin{minipage}{6cm}
\includegraphics[height=5cm,width=6.cm]{./Part6/figures/sperr.eps}
(b) results for different schemes
\end{minipage}
\caption{\label{regdy}(a) The locations of the
energy subregions $I$ and $II$, 
with different derivative features. Here the solid line denotes the 
observed cross section and the dashed line the corresponding derivative
value (with a scale factor of $10^{-2}$). 
(b) The fit uncertainties for the two measurement schemes, the crosses and 
the  diamonds denote, respectively, the results for the first and second 
schemes as described in the text.}
\end{center}
\end{figure}

To confirm the afore-mentioned speculation, 
two schemes are designed. In the first scheme, two points are taken in
region $I$, one at 3.55398 GeV as the threshold point and
the other at 3.5548 GeV corresponding to the energy point where
the derivative of the cross section is largest.  In addition
points are taken in
the region $II$, with the number of points $N_{pt}$ is
varied from 1 to 20, with each point having a 
luminosity of 5~pb$^{-1}$.  The fit
results for this scheme, displayed as crosses in 
Fig.~\ref{regdy}(b), show no improvement in precision
resulting from an increased number of data points 
tin region $II$
($S_{m_{\tau}}$ stays very near 0.25~MeV 
for any number of points).  To further examine 
this point, we investigated a second scheme, 
which only uses energy points in  region 
$II$, again with $N_{pt}$ varied from 1 to 20.
The fit results for this scheme are displayed 
as diamonds in Fig.~\ref{regdy}(b).
As expected, with the increasing number of points, $S_{m_{\tau}}$
decreases, but even with 20 points spread over region
$II$, the value of $S_{m_{\tau}}=0.7256$~MeV is still much larger than
that of $S_{m_{\tau}}$ with only two points in region $I$.
From this we conclude that the data taken
at energy points within region $I$ are much more
useful for optimal data taking.

\subsubsection{Optimal position}
In this subsection, we investigate the number of energy points that
are optimal in the large derivative region ($I$). 
Using a procedure similar to that described 
in Sect.~\ref{sect_opone}, the total luminosity
${\cal L}_{tot}=45$ pb$^{-1}$ is evenly distributed into $N_{pt}$
points ($N_{pt}=1,2, \cdots, 6$) inside the energy region 
between 3.553~GeV and 3.557~GeV. 
The results for  $S_{m_\tau}$
are shown in Fig.~\ref{sper}, where it is seen
that the number of points has a weak effect on the final uncertainty.
In other words, within the large derivative region, a single point 
is sufficient to give a small uncertainty. This is easy to understand 
since  there is only one free parameter ($m_{\tau}$) to be fit in the 
$\TT$ production cross section, even one measurement will fix
the normalization of the curve. The larger the derivative, the
more sensitivity to the mass of $\tau$ lepton.

\begin{figure}[htbp]
\center
\includegraphics[height=5cm,width=5.cm]{./Part6/figures/pt75.eps}
\caption{\label{sper}The relation between $S_{m_\tau}$
and the number of measurement points within the energy region 
between 3.553~GeV  and 3.555~GeV.}
\end{figure}

\begin{figure}[htbp]
\begin{center}
\begin{minipage}{6cm}
\includegraphics[height=5cm,width=6.cm]{./Part6/figures/scanfullintelog.eps}
(a) scan region from 3.551 to 3.595~GeV
\end{minipage}
\hskip 2cm
\begin{minipage}{6cm}
\includegraphics[height=5cm,width=6.cm]{./Part6/figures/scanlarinte.eps}
(b) 3.552~GeV to 3.5565~GeV scan region
\end{minipage}
\caption{\label{dvskn}The variation of $S_{m_\tau}$ {\it versus} 
energy from a one-point measurement with ${\cal L}_{tot}=45$ pb$^{-1}$.
(a) over the scan region from 3.551~GeV to 3.595~GeV 
(b) over the scan region from 3.5533~GeV to 3.55694~GeV. 
The solid line denotes the cross section derivative with a scale factor
of $10^{-3}$ and the dashed line the observed cross section
with a scale factor of $10^{-1}$.}
\end{center}
\end{figure}

If one point is enough, an immediate question is where is the optimal 
point located? To answer this, a one-point scan with the luminosity
${\cal L}_{tot}=45$ pb$^{-1}$ was made and the results are shown in 
Figs.~\ref{dvskn}(a) and (b). 
As indicated in previous study, the small uncertainty is near 
the peak of the derivative. Actually, the most precise result, 
$S_{m_\tau} =0.105$~MeV,
is obtained  at the $m_{\tau}$ threshold, at 3.55398~MeV;   
the measurement taken right
at the peak of the cross section derivative, 
$S_{m_\tau}$ is slightly worse.
In addition, the study indicates that within a 2~MeV region the 
variation of $S_{m_\tau}$ is fairly small 
(from 0.105~MeV to 0.127~MeV), which is
very good for actual data taking.

\subsubsection{luminosity and uncertainty}

The last question we investigate is the relation between
the uncertainty and the luminosity. For the fit with one 
point in the large-derivative region, results are listed in 
Table~\ref{lumauty}.
The second and third column present the results at
$E_{cm}=3.55398$~GeV, corresponding to the threshold while the
last two columns give the results at $3.55484$~GeV,
corresponding to the point with the largest 
cross section derivative. From the results
in Table~\ref{lumauty}, we see that the precision is
inversely proportional to the luminosity and a luminosity of
63 pb$^{-1}$ is sufficient to provide an accuracy 
of less than 0.1~MeV.

\begin{table}[htb]
\caption{\label{lumauty}The relation between luminosity and
uncertainty.}
\center
\begin{tabular}{ccccc} \hline \hline
$L_{tot}$ & \multicolumn{2}{c}{$E_{cm}=3.55398$ GeV}
                           & \multicolumn{2}{c}{$E_{cm}=3.5548$ GeV} \\
          & $Sm_\tau$  & $\Delta m_\tau$ & $Sm_\tau$ & $\Delta m_\tau$ \\
(pb$^{-1}$) 
          & (MeV)      &  (MeV)          & (MeV)     & (MeV)\\ \hline\hline
      9  & 0.24874  & 0.02931  & 0.29240  &$ 0.02114$ \\
     18  & 0.16926  & 0.01550  & 0.19635  &$ 0.00756$ \\
     27  & 0.14024  & 0.01234  & 0.15670  &$ 0.00475$ \\
     36  & 0.12130  & 0.00812  & 0.14384  &$ 0.00504$ \\
     45  & 0.10653  & 0.00824  & 0.12717  &$ 0.00292$ \\
     54  & 0.09783  & 0.00717  & 0.10714  &$-0.00037$ \\
     63  & 0.09035  & 0.00726  & 0.09923  &$-0.00003$ \\
     72  & 0.08424  & 0.00520  & 0.09297  &$ 0.00008$ \\
    100  & 0.06781  & 0.00129  & 0.07876  &$-0.00002$ \\
   1000  & 0.02146  & 0.00016  & 0.02515  &$ 0      $ \\
  10000  & 0.00684  & 0        & 0.00805  &$ 0      $ \\ \hline \hline
\end{tabular}
%\end{minipage}
\end{table}

\subsection{Discussion}\label{sect_dis}
At \bes3, the design peak luminosity 
is around 1 nb$^{-1}{\rm s}^{-1}$. If the average luminosity 
is taken to be 50\% of the peak value, two-days of data taking 
will give to 
a statistical uncertainty of less than 0.1~MeV. 
Notice that this evaluation 
is solely for $e\mu$-tagged event, other channels, 
such as $ee$, $e\mu$, $e h$, $\mu\mu$, $\mu h$ and $h h$ 
will have at least five times the number
of $e\mu$-tagged events~\cite{part6_taufirst,part6_taubes},
and these can significantly improve the uncertainty.
Therefore at \bes3, a one-week data-taking run will lead to a 
statistical uncertainty of order 0.017~MeV.



\section{Systematic uncertainty}
\label{part6:xct_sun}

In this section systematic uncertainties on $m_{\tau}$ measurements
will be examined, including the theoretical accuracy, energy spread,
energy scale, luminosity, efficiency, backgrounds, etc. 

\subsection{Theoretical accuracy}
The experimentally observed cross section has the form~\cite{part6_rad}
$$\sigma_{exp} (m_{\tau},s,\Delta)=\int_{0}^{\infty}
d\sqrt{s'} G(\sqrt{s'},\sqrt{s}) $$
\beq
\times \int_{0}^{ 1-\frac{ 4m_{\tau}^2 }{ s' } } dx F(x,s')
\frac{ \bar{\sigma}(s'(1-x),m_{\tau}) }{|1-\Pi (s'(1-x))|^2}~,
\label{expsec:2}
\eeq
where $s=E^2_{cm}$, $F(x,s)$ is the initial state radiation
factor~\cite{part6_rad}, $\Pi$ is the vacuum polarization
factor~\cite{part6_ruizf,part6_berends,part6_rodrigo}, and
$G(\sqrt{s'},\sqrt{s})$, describes the energy-spread
of the $e^+e^-$ collider, which is usually treated as a
Gaussian function~\cite{part6_vitual}, 
As mentioned in Sect.~\ref{part6:xct_int}, the high-accuracy 
calculations of the production cross section ($\bar{\sigma}$) 
have  only recently become available.
Voloshin's improved formulae~\cite{part6_voloshin}
are used here; the production cross section 
(denoted as $\bar{\sigma}^*$) used in in the BES-I $m_{\tau}$
fit was based on Voloshin's earlier results~\cite{part6_tauxcold}.
The relative differences in the cross sections calculated with
the two sets of Voloshin's formulae are shown in Fig.~\ref{cmpfmu}.

\begin{figure}[bth]
\begin{center}
\includegraphics[height=8.cm,width=9.cm]{./Part6/figures/cmpfmu.eps}
\caption{\label{cmpfmu}The relative differences of the 
latest and previous cross section
calculations from Voloshin~\cite{part6_tauxc}.
The result that includes effects of the beaam energy spread 
($\sigma_{exp}$) are shown as the solid line. 
Results without beam energy effects ($\bar{\sigma}$)
are shown as the dashed line.}
\end{center}
\end{figure}

To estimate the effect due to theoretical calculation accuracy,
the fitted $\tau$ masses by using the two formulae are compared.
The comparison shows the uncertainty due to this effect is at the
level of $10^{-3}$~MeV.

\subsection{Energy spread}
As indicated in Eq.~\eref{expsec:2}, the experimentally measured cross
section $\sigma_{exp}$ depends on the energy spread ($\Delta$); the
effect on the $m_{\tau}$ measurement is considered here.

In fact, the value of $\Delta$ in the $\tau$ 
threshold region is usually interpolated from 
the energy spreads measured at the $\jpsi$ ($\Delta_{\jpsi}$) and
$\psp$ ($\Delta_{\psp}$) regions, assuming the relation
\beq
\frac{\Delta - \Delta_{\jpsi}}{\Delta_{\psp} - \Delta_{\jpsi}}=
\frac{f(E) - f(E_{\jpsi})}{f(E_{\psp}) - f(E_{\jpsi})}~.
\label{eq_espd}
\eeq
It is assumed that $\Delta \propto f(E)$, where $f(E)$ denotes the
dependence of $\Delta$ on the beam energy $E_{cm}$.
Since a rigorous form for $f(E)$ is not available,
a generic form is assumed:
\beq
f(E)=a\cdot E + b\cdot E^2 + c\cdot E^3~,
\label{eq_fenerg}
\eeq
and linear, quadradiic, cubic or a mixed-type of energy-dependence
is used. 
At BES-I, the fit results give $\delta m_{\tau} < 1.5 \times 10^{-3}$ MeV.
Even if $\Delta$ is artificially changed to $3\Delta$ the fit indicates that
$\delta m_{\tau} < 6 \times 10^{-3}$ MeV.

\subsection{Energy scale}
 In the BES-I measurement, precisely known mass values of the $\jpsi$ 
($M_{\jpsi}$) and the $\psp$ ($M_{\psp}$) were used as the scale to 
calibrate  the energies in $\tau$ ($E_{\tau}$) 
threshold region,
\beq
\frac{E_{\tau} - E_{\jpsi}}{E_{\psp} - E_{\jpsi}}=
\frac{E_s - M_{\jpsi}}{M_{\psp} - M_{\jpsi}}~,
\eeq
where $E_s$ is the scaled energy value. If the energy and
mass peak have only a small relative shift $\delta$,
which in actuality are
at the level of $10^{-4}$, the relation can be written as
\beq
\frac{E_s - M_{\jpsi}}{M_{\psp} - M_{\jpsi}}=
\frac{\delta_s - \delta_{\jpsi}}{\delta_{\psp} - \delta_{\jpsi}}~.
\label{eq_escale}
\eeq
Similar to the energy spread, if we could assume
$\delta \propto f(E)$, the uncertainty due to the energy scale
would only be about $8 \times 10^{-3}$ MeV.

%\subsection{Absolute energy calibration}
However, the relation $\delta \propto f(E)$ is merely a speculation and
probably not a safe assumption. 
At present, there are two approaches to determine the absolute energy 
scale directly, one is depolarization and the other is Compton back-scattering, 
both were developed by the KEDR group~\cite{part6_taukedr}.

\begin{figure}[bth]
\begin{center}
\includegraphics[height=5.cm,width=6.cm]{./Part6/figures/eskeff.eps}
\caption{\label{eskeff}The effects of uncertainty in the absolute
energy calibration on $m_{\tau}$ measurement.}
\end{center}
\end{figure}

It is proposed to adopt the Compton back-scattering technique to
measure the BEPCII beam energies. The relative precision of this technique 
is expected to be at the $5 \times 10^{-5}$ level, which directly 
translates to a systematic uncertainty on $m_{\tau}$ of
$5 \times 10^{-5}$ (relative error) or 
$0.09$ MeV (absolute error).  This error is an
 order-of-magnitude  larger than the 
combined error from other sources,
which is $8 \times 10^{-3}$~MeV.
Since the uncertainty of the energy scale will transfer 
directly to the final 
$m_{\tau}$ measurement as displayed in Fig.~\ref{eskeff},
the absolute calibration of energy scale is the
\underline{bottleneck} for the $m_{\tau}$ measurement.

\subsection{Other factors}
The systematic uncertainties due to other experimental factors are quantified
by reasonable variations of the corresponding quantities, as listed
in Table~\ref{sytuty}. The total uncertainty is estimated to be
at the level of 0.1 MeV. 

\begin{table}[htb]
\caption{\label{sytuty}Systematic uncertainties for $m_{\tau}$
measurement.} \center
\begin{tabular}{ccc} \hline \hline
Source & $\delta m_\tau$           & $\delta m_\tau/m_\tau$  \\
       & ( $10^{-3}$ MeV)          &  ( $10^{-6}$ )         \\ \hline\hline
Luminosity (2\%)           &   14.0     &    7.9   \\
Efficiency (2\%)           &   14.0     &    7.9   \\
Branching Fraction (0.5\%) &   3.5      &    2.0   \\
Background (10\%)          &   1.7      &    1.0   \\
Energy spread (30\%)       &   3.0      &    1.7   \\
Theoretical accuracy       &   3.0      &    1.7   \\
Energy scale               & 100        &   56.3   \\ \hline 
Summation                  & 102 & 57.5  \\  \hline\hline
\end{tabular}
\end{table}
%\begin{table}[htb]
%\caption{\label{sytuty}Some possible systematic uncertainties.}
%\center
%\begin{tabular}{ccc} \hline \hline
%Source & $\delta m_\tau$           & $\delta m_\tau/m_\tau$  \\
%       & ( $10^{-3}$ MeV)          &  ( $10^{-6}$ )         \\ \hline\hline
%Theoretical accuracy  &   3        &        1.7   \\
%Energy spread         &   6        &        3.4   \\
%Energy scale          &$\dagger 8$ &$\dagger 4.5$ \\
%Luminosity            &   14       &    7.9   \\
%Efficiency            &   14       &    7.9   \\
%Branching Fraction    &   3.5      &    2.0   \\
%Background            &   1.7      &    1.0   \\  \hline
%Summation             &   22.7     &    12.7  \\  \hline\hline
%\end{tabular}\\
%$\dagger$: based on the estimation of Eq.~(\ref{eq_escale}).
%\end{table}
%

\section{Energy measurement at \bes3}
\label{part6:xct_egskbes3}

As we mentioned above, the absolute energy calibration plays a crucial
role in the $\tau$ mass measurement. A technique based on the Compton 
back-scattering principle is proposed to measure measure the 
BEPCII beam  energies with high precision.

The detection system would be located at the north interaction 
point (IP) of the BEPCII storage ring as shown in 
Figs.~\ref{psnofdet}~and~\ref{fig:engmsys}.

\begin{figure}[bthp]
\center
\includegraphics[height=8.cm,width=10.cm]{./Part6/figures/bepcsr.eps}
\caption{\label{psnofdet}The location of the energy measurement
system at in BEPCII.}
\includegraphics[height=8.cm,width=10.cm]{./Part6/figures/opt.eps}
\caption{\label{fig:engmsys}A schematic diagram of
the layout for the energy measurement
system. The two black cured lines denote the positron and electron beams.
The bottle-like box ($A$) indicates the laser source; the circled dot ($B$)
indicates the HPGe detector; rectangles ($C$) denote 
BEPCII bending magnets; $a$ indicates
a half-transmissive/half-reflective lens; $b$'s indicate 
reflective lenes and $f$'s indicate focusing lenses.}
\end{figure}

%\begin{figure}[bth]
%\center
%\setlength{\unitlength}{0.12cm}
%
%\begin{picture}(100,35)
%\linethickness{0.5mm}
%\qbezier(0,15)(20,15)(50,25)
%\qbezier(50,25)(75,30)(100,30)
%\qbezier(100,15)(80,15)(50,25)
%\qbezier(50,25)(25,30)(0,30)
%%\put(5,30){\vector(-1,0){1.}}
%%\put(95,30){\vector(1,0){1.}}
%\put(2,29.7){\makebox(0,0){{\Large $\leftarrow$}}}
%\put(98,29.7){\makebox(0,0){{\Large $\rightarrow$}}}
%\put(5,19){\makebox(0,0){{\huge $e^-$}}}
%\put(95,19){\makebox(0,0){{\huge $e^+$}}}
%
%
%\linethickness{0.3mm}
%\put(0,15){\line(1,0){100}}
%\put(50,15){\circle*{2.5}}
%\put(50,5){\makebox(0,0){{\Huge $\ast$}}}
%\put(60.5,4.95){\usebox{\talupleft}}
%\put(36.5,4.95){\usebox{\talupright}}
%\put(36.5,15.){\usebox{\taldwleft}}
%\put(60.35,15.){\usebox{\taldwright}}
%\put(49.5,5){\line(-1,0){11.5}}
%\put(50.5,5){\line(1,0){11.5}}
%\put(38,5){\line(0,1){10.3}} 
%\put(62,5){\line(0,1){10}}   
%
%\put(38,10){\makebox(0,0){{\normalsize $\uparrow$}}}
%\put(62,10){\makebox(0,0){{\normalsize $\uparrow$}}}
%\put(30,14.9){\makebox(0,0){{\normalsize $\leftarrow$}}}
%\put(70,14.9){\makebox(0,0){{\normalsize $\rightarrow$}}}
%\put(45,14.9){\makebox(0,0){{\normalsize $\rightarrow$}}}
%\put(55,14.9){\makebox(0,0){{\normalsize $\leftarrow$}}}
%
%%\put(38,10){\vector(0,1){1.}}
%%\put(62,10){\vector(0,1){1.}}
%%\put(30,15){\vector(-1,0){1.}}
%%\put(70,15){\vector(1,0){1.}}
%%\put(45,15){\vector(1,0){1.}}
%%\put(55,15){\vector(-1,0){1.}}
%\end{picture}
%\caption{\label{fig:engmsys}The schmatical plot of energy measurement
%system. The star $\ast$ indicates the laser source; the solid circle $\bullet$
%indicates the HPGe detector; the triangles denotes the optics system
%schmatically. The arrows indicate the propagagton direction of laser beams or
%electron beams.}
%\end{figure}

The proposed beam energy measurement system (denoted as energy detector 
in Fig.~\ref{psnofdet}) is comprised of the following parts: 
%(classified
%for easily understanding the general mechanism of the whole system) :
\begin{enumerate}
\item the laser source and optics system;
\item the interaction regions where the laser beams collides with the 
electron or
positron beam;
\item a high purity Geranium detector (HPGe) to measure back-scattering
high energy $\gamma$-rays or $X$-rays.
\end{enumerate}

In the following subsections, we will describe each subsystem.
In operation, the energy measured at the north IP has to be 
corrected for synchrontron radiation produced by
the beams when the travel to the collision point
in the south intersection point.  This is at the level 
of 200 keV, with a corresponding uncertainty that is less 
than 10\%, or, equivalently, 20 keV.

\subsection{Laser source and optics system}
A simple and extensively used expression for a
laser beam amplitude is~\cite{part6_bk:wscChang}
\beq
\psi(x,y,z)=C \cdot \exp \left[ -\frac{x^2+y^2}{r^2(z)}\right] \cdot
\exp \left[ i \theta(x,y,z) \right]~.
\label{gstem00}
\eeq
Here $\psi(x,y,z)$ describes a TEM$_{00}$ mode Gaussian beam, where TEM is the 
abbreviation for transverse electric and magnetic wave. 
In Eq.~\eref{gstem00}, $\theta(x,y,z)$ is a phase factor and $r(z)$ is a 
function of $z$ (the propagation distance):
\beq
r(z)= r_0 \sqrt{1+\left( \frac{z}{z_0} \right)^2},
~~z_0=\frac{\pi r_0}{\lambda}~,
\label{xpn_raz}
\eeq
where $r_0$ is the waist width of laser beam given at $z=0$ and $\lambda$ is 
the wavelength of the laser beam. Using Eq.~\eref{gstem00}, we  
obtain the photon density in the laser beam to be
\beq
\rho_{\gamma} = |\psi(x,y,z)|^2 =
\rho_0 \cdot f_{\gamma}(x,y,z), ~~
f_{\gamma}(x,y,z) = \exp \left[ -\frac{2(x^2+y^2)}{r^2(z)}\right]~. 
\label{rholaser}
\eeq
To determine the constant $\rho_0~(=C^2)$ in Eq.~\eref{rholaser}, we 
consider
the differential relation between the laser power ($P$) and 
the photon density:
\beq
dP = \omega_{\gamma} \cdot \rho_{\gamma} \cdot \Delta S \cdot c~,
\label{prrelation}
\eeq
where $\omega_{\gamma}$ is the energy of laser beam, $c$ the velocity of light, 
and $\Delta S$ is a cross-sectional area element of the laser beam.
Integrating the above relation:
$$P=\int dP =
\omega_{\gamma} \cdot \rho_0 \cdot c \int \int f_{\gamma}(x,y,z) dxdy~,$$
we find
$$P=\rho_0 \cdot ( \omega_{\gamma} \cdot c \cdot \pi \cdot r^2(z))~,$$
or
\beq
\rho_0 = \frac{P}{\omega_{\gamma} \cdot c \cdot \pi \cdot r^2(z)}~.
\label{fatrho0}
\eeq
From dimensional analysis, we notice that $\rho_0$ has dimension of inverse
volume, so the photon density $\rho_{\gamma}$ is actually a volume 
density distribution.
 
\subsection{Electron beam} 
Similarly, the density function for
the electron (positive or negative) beam
can  be expressed as
\beq
\rho_{e} = \rho^{\prime}_0 \cdot f_{e}(x,y,z), ~~
f_{e}(x,y,z) = \exp \left[ - \left( \frac{x^2}{\sigma^2_x} 
 + \frac{y^2}{\sigma^2_y} \right) \right]~, 
\label{rhoelek}
\eeq
where $\sigma_x$ and $\sigma_y$ are standard deviations of electron beam
in $x$ and $y$ directions, respectively; $\rho^{\prime}_0$ is the normalization 
factor which is determined by the differential relation between the 
current intensity ($I$) and electron density:
\beq
dI = e \cdot \rho_{e} \cdot \Delta S \cdot u_e~,
\label{perelation}
\eeq
where $e$ is the electron charge, $u_e$ is the velocity of electron beam, 
and $\Delta S$ is a cross-sectional area element of the electron beam. 
From the integration of the above relation:
$$I=\int dI =
e \cdot \rho^{\prime}_0 \cdot u_e \int \int f_{e}(x,y,z) dxdy~,$$
we get
$$P=\rho^{\prime}_0 \cdot ( u_e \cdot e \cdot \pi \cdot
\sigma_x \sigma_y)~,$$
or
\beq
\rho^{\prime}_0 = \frac{I}{u_e \cdot e \cdot \pi \cdot \sigma_x \sigma_y}~.
\label{fatrhop0}
\eeq
From dimensional analysis, we notice that $\rho^{\prime}_0$ has dimension of 
inverse volume, so the electron density $\rho_{e}$ is actually a volume 
density 
distribution.

\subsection{Compton back-scattering principle}
The interaction of the electron and laser beams is described by 
the Compton back-scattering 
principle~\cite{part6_bk:pRullhusenetal,part6_bk:ldLandau}. 
The energy of the back-scattered photon ($\omega_2$) is
\beq
\omega_2 = \frac{\omega_1 (1- \beta \cos \phi_1)}
{1- \beta \cos \phi_2+
{\displaystyle \frac{\omega_1}{\gamma m}} (1- \cos [\phi_1 - \phi_2])}~~.
\label{eq:omega2}
\eeq
When unpolarized light is scattered by unpolarized electrons and
neither the spin of the residual electron nor the polarization of the
final photon are observed, the differential cross section 
can be expressed in terms of 
relativistic invariants as %% ~\cite{part6_bk:ldLandau}
\beq
\frac{d\sigma}{dt} = 2 \pi r^2_0 \frac{1}{(m x_1)^2}
\left\{4y(1+y) -\frac{x_1}{x_2}-\frac{x_2}{x_1} \right\}~,
\label{eq:dsigdt}
\eeq
where $r_0$ is the classical electron radius and 
\begin{eqnarray}
x_1&=& 2 \gamma {\displaystyle\frac{\omega_1}{m}}(1- \beta \cos \phi_1)~, 
\label{eqn:x1} \\ 
x_2&=& -2 \gamma {\displaystyle\frac{\omega_2}{m}}(1- \beta \cos \phi_2)~,
\label{eqn:x2} \\
y&=& {\displaystyle \frac{1}{x_1} + \frac{1}{x_2} } ~.
\label{eqn:y}
\end{eqnarray}
In a scattering experiment, $s$ (and therefore $x_1$) is fixed by the
energies of the initial electron and photon. The total cross section 
is obtained from Eq.~\eref{eq:dsigdt} using $t=-m^2(x_1+x_2)$ and
integrating over $x_2$ at a fixed value of $x_1$ 
%%(see e.g. Ref.~\cite{part6_bk:ldLandau})
\beq
\sigma = 2 \pi r^2_0 \frac{1}{x_1} 
\left\{ \left(1-\frac{4}{x_1}-\frac{8}{x^2_1} \right) \ln (1+x_1) 
+\frac{1}{2}+\frac{8}{x_1}-\frac{1}{2(1+x_1)^2} \right\}~,
\label{eq:intsig}
\eeq
When observed in the laboratory, however, the Lorentz 
transformation concentrates the photon flux into a small 
cone with half-angle $\phi_2$ of
the order of $1/\gamma$, which
increases  the photon flux at backward scattering
angles.  In Ref.~\cite{part6_bk:jmRauch}, the differential cross 
section per unit solid angle is given by
\beq
\frac{d\sigma}{d\Omega} = 2 r^2_0 
\left( \frac{\omega_2}{m x_1} \right)^2
\left\{4y(1+y) -\frac{x_1}{x_2}-\frac{x_2}{x_1} \right\}~.
\label{eq:dsigdmg}
\eeq
The formulae in Eqs.~\ref{eq:intsig} and~\ref{eq:dsigdmg} are used 
below to calculate the interaction rate between the laser beam and
the high energy electron beam.

\subsection{A simple simulation}\label{sbxct_sisisy}

Based on the principles introduced above, we establish a simplified
system to simulate the procedure of the absolute energy measurement. 
We evaluate the intensity of the back-scattered photons
and simulate the detected photon energy distribution. Finally, the 
precison of the beam energy measurement is obtained. 
%\subsubsection{intensity of back-scattering photon}

The intensity of back-scattered photons can be calcuated by the following 
formula:
\beq
N_{\gamma} = u_e \sigma_T \cdot
\int  \int \int~ \rho_{\gamma} \cdot \rho_e~ dxdydz
\eeq
where $\rho_{\gamma}$ denotes the volume density of the laser beam
described by Eqs.~\ref{rholaser} and~\ref{fatrho0}; 
$\rho_e$ is the volume density of the electron beam described by
Eqs.~\ref{rhoelek} and~\ref{fatrhop0};
$\sigma_T$ is the total cross section given in Eq.~\ref{eq:dsigdmg} 
(or approximately by Eq.~\ref{eq:intsig}).  
We can rewrite the above equation as:
\beq
N_{\gamma} = \frac{PI \sigma_T}{\omega_{\gamma} \cdot c \cdot e \cdot \pi^2}
\int  \int \int~ \frac{1}{r^2(z)} f_{\gamma} \cdot f_{e}~ dxdydz~.
\label{ngamma}
\eeq

Inserting the parameters provided in Table~\ref{parmtlsrelk} into
Eq.~\ref{ngamma}, we find
$$ N_{\gamma} = 2.7 \times 10^8 s^{-1}~.$$

\begin{table}[htb]
\caption{\label{parmtlsrelk}Some input parameters for the laser and 
electron beam.}
\center
\begin{tabular}{ll} \hline \hline
     laser beam                               & electron  beam       \\ \hline 
  power P= 50 W                               & $I$ = 9. 8 mA        \\
  wave-length $\lambda$ = 10. 59 $\mu$ m      & $\sigma_x$ = 1.6 mm  \\
  laser energy $\omega_{\gamma}$ =0.117 eV    & $\sigma_y$ = 0.16 mm \\
  waist radius $r_0$ = 2mm                    & $\sigma_z$ = 15 mm   \\
\hline \hline
\end{tabular}
\end{table}

%\subsubsection{distribution of photon detected by HPGe}
The detection of the back-scattered photons 
in the HPGe is simulated using the GEANT4 
package~\cite{part6_fucda}. Figure~\ref{smhpge} shows the photon 
energy spectrum, where a clear Compton edge is evident;
this edge is used  the measure the absolute beam energy.

\begin{figure}[hbt]
\begin{minipage}{7.5cm}
\centerline{\psfig{file=./Part6/figures/genew.eps,height=6.0cm ,width=7.5cm}}
(a) The detected photon energy spectrum between 0 and 6~MeV.
\end{minipage}
\hskip 1.0 cm
\begin{minipage}{7.5cm}
\centerline{\psfig{file=./Part6/figures/gefit.eps,height=6.0cm ,width=7.5cm}}
(b) the detected photon energy spectrum between 5.43~MeV and 5.64~MeV
\end{minipage}
\caption{\label{smhpge} The simulated photon energy spectrum measured by 
the HPGe detector.}
\end{figure}

The edge of the Compton spectrum is fitted with the six parameter
function~\cite{part6_nMuchnoi}:
\beq
g(x,\vec{p})=\frac{1}{2}(p_2(x-p_0)+p_3)\cdot
\mbox{erfc} \left[ \frac{x-p_0}{\sqrt{2} p_1}\right]-
\frac{p_1 p_2}{\sqrt{2\pi}} \cdot 
\exp \left[-\frac{(x-p_0)^2}{2 p^2_1}\right]+
p_4(x-p_0)+p_5~, 
\label{cmpedgft}
\eeq
where $p_0$ is the edge position; 
$p_1$ is the edge width; $p_2$ is the left slope; $p_3$ is the edge 
amplitude;
$p_4$ is the right slope; and $p_5$ is the background. 
The $p_0$ parameter
gives the information about the average electron beam energy 
during the data acquisiton period, while $p_1$ is mostly coupled 
to the electron beam energy spread. 

%\subsection{Discussion}
In addition to the simple simulation described above, 
a number of factors have to
be taken into account in a real measurement, inluding: the effect
of the focusing system on the laser beam,  the dynamics and trajectories
of the electron beam, the calibration of the HPGe detector, etc., 
in order to estimate the accuracy of the beam energy measurement. 
%in section~\ref{sbxct_sisisy} 
%is a rather simplified system where a variety of actaul factors have not been 
%taken into accunt. Some of them are listed as follows 
%
%\begin{enumerate}
%\item Laser and optics system: if the laser cavity length $L=750$ mm, and
%using formula $\theta_{rad}=2\sqrt{(2\lambda)/(L\pi)}$, the radiation beam-wdith 
%is estimated around $\theta_{rad} \approx 6 \times 10^{-3}~rad $. So the beam diameter 
%at 6 or 9 meter away from laser source is around 40 or 60 mm. Under such case
%the optics system is needed to focus the laser beam. In addition, the uncertainty
%due to the optics system should also be taken into consideration in detailed 
%simulation system. 
%
%\item Interaction region: in simple simulation system the ``head-on'' collision 
%is assumed between the laser and electron beams, but actual situation is much
%more complicate, theelectron beam have not only vertical but also horizontal deviations:
%\begin{itemize}
%\item Vertical deviation is engineer deviation, its value is fixed, 
%$\alpha_H = 0.155 rad$;
%\item Horizontal deviation is mode deviation, its value depends on the energy, 
%running mode and other factors, $\alpha_V = 1.1 (1\pm 20\%) \mbox{m}rad$ at
%$E_{cm}= 1.77699$ GeV;
%\item Vertical and Horizontal devations do not happen at the same place. 
%\end{itemize}
%Moreover, the energy spread effect should also be considered.
%
%\item HPGe Detector system: here more technique details should be considered which
%will be discussed elsewhere. 
%\end{enumerate}

\section{Summary}
\label{part6:xct_sum}

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
The statistical and systematic uncertainties of  a $m_{\tau}$
measurement at \bes3 are studied based on
previous experience and recent theoretical calculations. Monte Carlo
simulation and sampling techniques are employed to obtain an optimal
data taking strategy. It is found that:
\begin{enumerate}
\item the optimal measurement energy is located near the point with 
the largest derivative of the cross section with respect to energy;
\item one measurement point in this region is sufficient to provide the 
smallest statistical error for a given amount of integrated luminosity;
\item an integrated  luminosity of 63 pb$^{-1}$ will produce  a 
statistical accuracy that is better than 0.1 MeV.
\end{enumerate}

In addition, many factors have been taken into account to estimate possible
systematic uncertainties. The expected total relative error is at the 
level of $5.8 \times 10^{-5}$. The absolute calibration of energy scale 
will be crucial for further improvement of the accuracy of the $m_{\tau}$ 
measurement.
If the laser back-scattering  technique is applied at \bes3, an
ultimate systematic uncertainty of around 0.09 MeV could be achieved.

%\section*{Acknowledgment }
%\indent
%Author would like to acknowledge help from his graduated student Y.K. Wang
%who work hard on actual fits.
%Thanks are also due to Prof. C.Z. Yuan who gave many valuable suggestions and
%comments for improvement of the proceedings.